Original installation | ARGIA lighting solution | |
---|---|---|
Type of luminary | Mercury discharge lamps 250 W | LEDIKO INLEN2 M2 DALI, INDUSTRY LINE AL |
Number of luminaires | 70 pcs | 52 pcs |
Total Input | 20.29 kW | 6.05 kW |
Consumption kWh/year | 101,430 kWh | 24,216 kWh |
Project result | Customer’s total operating costs reduced by 76% thanks to the combination of LED luminaires and DALI control via daylight and motion sensors when increased illumination level by 40%. | |
Return on investment | 2.5 years |
Type of luminary | LEDIKO INLEN2 M2 DALI, INDUSTRY LINE AL |
Number of luminaires | 52 ks |
Total Input | 6.05 kW |
Consumption kWh/year | 24216 kWh |
Project result | Customer’s total operating costs reduced by 76% thanks to the combination of LED luminaires and DALI control via daylight and motion sensors when increased illumination level by 40%. |
Return on investment | 2.5 years |
Installation parameters:
For SEEIF Ceramic a.s., the manufacturer of ceramic components for the construction industry, we have replaced in full operation and without its interruption existing non-conforming discharge lluminaires for new modern DALI LED luminaires. There are furnaces for burning ceramic products, which place higher demands on the temperature resistance of the luminaires. The workplaces of the presses were illuminated by individualy switched luminaires. DALI control allows to set different levels of illumination for each activity. The use of energy saving and temperature resistant LED luminaires combined with DALI control with daylight and motion sensors give a superior 76% operating cost savings to the customer with a 40% increase of illumination.