References
GREINER PACKAGING

GREINER PACKAGING

Renovation
LOUKA U LITV√ćNOVA, CZE
Warehouse
Industrial lighting
Annual energy savings 405,449 kWh
75 %

Original installation

Original installation ARGIA lighting solution
Type of luminary Fluorescent luminaires T8 2x58W INLENE 2 M3 185W
Number of luminaires 454 pcs 100 pcs
Total Input 62.65 kW 18.50 kW
Consumption kWh/year 541,313 kWh 135,864 kWh
Project resultThe total customer operating costs has been reduced by 75% with high quality lighting throughout the rack height.
Return on investment 2 years

ARGIA lighting solution

Type of luminary

INLENE 2 M3 185W

Number of luminaires 100 ks
Total Input18.5 kW
Consumption kWh/year 135864 kWh
Project resultThe total customer operating costs has been reduced by 75% with high quality lighting throughout the rack height.
Return on investment 2 years

Installation parameters:

  • Controll with motion sensors
  • Connecting 50% of luminaires to UPS
  • High quality illumination throughout shelf heights
  • High installation height 11 m
  • Full 5-year warranty

For Greiner Packaging s.r.o., a manufacturer of plastic food packaging, we have exchanged out-of-date T8 fluorescent lamps for new modern LEDs with special optics in the rack warehouse area, during the planned shutdown. The luminaires were installed at an altitude of 11 meters, requiring high uniformity and high-quality lighting throughout the rack height. Luminaires are controlled by motion sensors in individual rack lanes and 50% of them are connected to UPS backup sources. By installing modern LED luminaires with special optics and motion sensor control, the customer has saved operating costs of 75% and got a significant improvement in working conditions.